-Menu 8 REGLAGE TECHNIQUE+==== Menu 8 REGLAGE TECHNIQUE ====
 => CLE D'ACCES = A9 => CLE D'ACCES = A9
- M-8-1 TYPE GRANULES + 
- M-8-1-01 CHARGE GRANULES : -9~0~+9 Reglage Usine:0 +=== M-8-1 TYPE GRANULES === 
-  +  M-8-1-01 CHARGE GRANULES : -9~0~+9 Reglage Usine:0 
- M-8-2 TYPE CHEMINEE +  
- M-8-2-01 ASPI FUME CHEMINEE: -9~0~+9 Reglage Usine:0 +=== M-8-2 TYPE CHEMINEE === 
-   +  M-8-2-01 ASPI FUME CHEMINEE: -9~0~+9 Reglage Usine:0 
- M-8-3 BANQUE DONNEE +    
-  +=== M-8-3 BANQUE DONNEE === 
- M-8-4 REGLAGE GENERAL + 
- M-8-4-01 BLOCAGE RALLUMAGE : Reglage Usine:05' +=== M-8-4 REGLAGE GENERAL === 
- M-8-4-02 ASP MIN ETEINT : Reglage Usine:02' +  M-8-4-01 BLOCAGE RALLUMAGE : Reglage Usine:05' 
- M-8-4-03 PRECHARGE ALLUMAGE : Reglage Usine:60" +  M-8-4-02 ASP MIN ETEINT : Reglage Usine:02' 
- M-8-4-04 ATTENTE FLAMME : Reglage Usine:60" +  M-8-4-03 PRECHARGE ALLUMAGE : Reglage Usine:60" 
- M-8-4-05 ASP FUME PRECHARGE : Reglage Usine:1850 +  M-8-4-04 ATTENTE FLAMME : Reglage Usine:60" 
- M-8-4-06 DELTA ON oFF AUTO : Reglage Usine:01.0°c +  M-8-4-05 ASP FUME PRECHARGE : Reglage Usine:1850 
- M-8-4-07 RETA OFF AUTO : Reglage Usine:02' +  M-8-4-06 DELTA ON oFF AUTO : Reglage Usine:01.0°c 
- M-8-4-08 CHANGE PUISSANCE : Reglage Usine:40" +  M-8-4-07 RETA OFF AUTO : Reglage Usine:02' 
- M-8-4-09 VENTIL EN OFF : Reglage Usine:220V +  M-8-4-08 CHANGE PUISSANCE : Reglage Usine:40" 
- M-8-4-10 BLOCAGE CLAVIER: Reglage Usine:off +  M-8-4-09 VENTIL EN OFF : Reglage Usine:220V 
- M-8-4-11 BLACK OUT : Reglage Usine:15" +  M-8-4-10 BLOCAGE CLAVIER: Reglage Usine:off 
- M-8-4-12 HEURES SERVICES : Reglage Usine:2000 +  M-8-4-11 BLACK OUT : Reglage Usine:15" 
-  +  M-8-4-12 HEURES SERVICES : Reglage Usine:2000 
- M-8-5 TEST SORTIE + 
- M-8-5-01 TEST BOUGIE : off/on +=== M-8-5 TEST SORTIE === 
- M-8-5-02 TEST VISANFIN : 0 4 +  M-8-5-01 TEST BOUGIE : off/on 
- M-8-5-03 TEST FUMEE : off/225U +  M-8-5-02 TEST VISANFIN : 0 4 
- M-8-5-04 TEST VENTIL : off/225U +  M-8-5-03 TEST FUMEE : off/225U 
-  +  M-8-5-04 TEST VENTIL : off/225U 
- M-8-6 REGLAGE D +  
- M-8-6-01 MINUTES TIME-OUT: 00' +=== M-8-6 REGLAGE D === 
- M-8-6-02 MINUTES DEMARRAG: 02' +  M-8-6-01 MINUTES TIME-OUT: 00' 
- M-8-6-03 NETTOYAGE BRASERO: 30' +  M-8-6-02 MINUTES DEMARRAG: 02' 
- M-8-6-04 VISANFIN ALLUMAGE: 1.2" +  M-8-6-03 NETTOYAGE BRASERO: 30' 
- M-8-6-05 VISANFIN DEMARRAG: 1.5" +  M-8-6-04 VISANFIN ALLUMAGE: 1.2" 
- M-8-6-06 VISANFIN PUISSAN1: 1.0" +  M-8-6-05 VISANFIN DEMARRAG: 1.5" 
- M-8-6-07 VISANFIN PUISSAN2: 1.2" +  M-8-6-06 VISANFIN PUISSAN1: 1.0" 
- M-8-6-08 VISANFIN PUISSAN3: 1.5" +  M-8-6-07 VISANFIN PUISSAN2: 1.2" 
- M-8-6-09 VISANFIN PUISSAN4: 1.9" +  M-8-6-08 VISANFIN PUISSAN3: 1.5" 
- M-8-6-10 VISANFIN PUISSAN5: 2.3" +  M-8-6-09 VISANFIN PUISSAN4: 1.9" 
- M-8-6-11 RETARD ALARME: 50" +  M-8-6-10 VISANFIN PUISSAN5: 2.3" 
- M-8-6-12 NETTOYAG BRASERO: 24" +  M-8-6-11 RETARD ALARME: 50" 
- M-8-6-13 SEUIL MINIMUM: 45°c +  M-8-6-12 NETTOYAG BRASERO: 24" 
- M-8-6-14 SEUIL MAXIMUM: 275°c +  M-8-6-13 SEUIL MINIMUM: 45°c 
- M-8-6-15 SEUIL VENTILAT: 60°c +  M-8-6-14 SEUIL MAXIMUM: 275°c 
- M-8-6-16 ALL-FUME VITESSE: 1850 +  M-8-6-15 SEUIL VENTILAT: 60°c 
- M-8-6-17 DEM-FUME VITESSE: 1600 +  M-8-6-16 ALL-FUME VITESSE: 1850 
- M-8-6-18 FUME VITESS 1: 1650 +  M-8-6-17 DEM-FUME VITESSE: 1600 
- M-8-6-19 FUME VITESS 2: 1780 +  M-8-6-18 FUME VITESS 1: 1650 
- M-8-6-20 FUME VITESSE : 1880 +  M-8-6-19 FUME VITESS 2: 1780 
- M-8-6-21 FUME VITESSE : 2000  +  M-8-6-20 FUME VITESSE : 1880 
- M-8-6-22 FUME VITESS 5: 2180 +  M-8-6-21 FUME VITESSE : 2000  
- M-8-6-23 VITESSE VENTIL 1: 65U +  M-8-6-22 FUME VITESS 5: 2180 
- M-8-6-24 VITESSE VENTIL 2: 160U +  M-8-6-23 VITESSE VENTIL 1: 65U 
- M-8-6-25 VITESSE VENTIL 3: 185U +  M-8-6-24 VITESSE VENTIL 2: 160U 
- M-8-6-26 VITESSE VENTIL 4: 200U +  M-8-6-25 VITESSE VENTIL 3: 185U 
- M-8-6-27 VITESSE VENTIL 5: 225U +  M-8-6-26 VITESSE VENTIL 4: 200U 
- M-8-6-28 SEUIL ARRET: 50°c +  M-8-6-27 VITESSE VENTIL 5: 225U 
- M-8-6-29 ASP-FUME NETTOYAG: 2500 +  M-8-6-28 SEUIL ARRET: 50°c 
- M-8-6-30 VISANFIN NETTOYAG: 1.0"  +  M-8-6-29 ASP-FUME NETTOYAG: 2500 
- M-8-6-31 ENCODER: on +  M-8-6-30 VISANFIN NETTOYAG: 1.0"  
- M-8-6-32 INTERRUP TEMPS: 0.2" +  M-8-6-31 ENCODER: on 
- M-8-6-33 PREMIER NETTOYAG: 20" +  M-8-6-32 INTERRUP TEMPS: 0.2" 
- M-8-6-34 TEMPS PRECHAU: 90" +  M-8-6-33 PREMIER NETTOYAG: 20" 
- M-8-6-35 VIT-FUME PREM-NET: 2500 +  M-8-6-34 TEMPS PRECHAU: 90" 
- M-8-6-36 VIT-FUME PR(ECHAUFFAGE): 1800 +  M-8-6-35 VIT-FUME PREM-NET: 2500 
- M-8-6-37 VIT-FUME ATTENTE: 1750 +  M-8-6-36 VIT-FUME PR(ECHAUFFAGE): 1800 
-  +  M-8-6-37 VIT-FUME ATTENTE: 1750 
-  +   
-  +   
- M-8-7 EFFACER H PARTIEL +   
- => CLE D'ACCES = 55 +=== M-8-7 EFFACER H PARTIEL === 
-  + => CLE D'ACCES = 55 
- M-8-8 EFFACER ALARME +  
- => CLE D'ACCES = 55 +=== M-8-8 EFFACER ALARME === 
-  + => CLE D'ACCES = 55 
- M-8-9 MEMOIRE COMPTEUR +  
- HEURE TOTALE +=== M-8-9 MEMOIRE COMPTEUR === 
- HEURE PARTIEL +  HEURE TOTALE 
-  +  HEURE PARTIEL 
- M-8-A VOLT ASP FUMEE+  
 +=== M-8-A VOLT ASP FUMEE ===