Ligne 1: | Ligne 1: | ||
- | Menu 8 REGLAGE TECHNIQUE | + | ==== Menu 8 REGLAGE TECHNIQUE |
=> CLE D' | => CLE D' | ||
- | M-8-1 TYPE GRANULES | + | |
- | M-8-1-01 CHARGE GRANULES : -9~0~+9 Reglage Usine:0 | + | === M-8-1 TYPE GRANULES |
+ | | ||
- | M-8-2 TYPE CHEMINEE | + | === M-8-2 TYPE CHEMINEE |
- | M-8-2-01 ASPI FUME CHEMINEE: -9~0~+9 Reglage Usine:0 | + | |
- | M-8-3 BANQUE DONNEE | + | === M-8-3 BANQUE DONNEE |
+ | |||
+ | === M-8-4 REGLAGE GENERAL === | ||
+ | * M-8-4-01 BLOCAGE RALLUMAGE : Reglage Usine: | ||
+ | * M-8-4-02 ASP MIN ETEINT : Reglage Usine: | ||
+ | * M-8-4-03 PRECHARGE ALLUMAGE : Reglage Usine: | ||
+ | * M-8-4-04 ATTENTE FLAMME : Reglage Usine: | ||
+ | * M-8-4-05 ASP FUME PRECHARGE : Reglage Usine: | ||
+ | * M-8-4-06 DELTA ON oFF AUTO : Reglage Usine: | ||
+ | * M-8-4-07 RETA OFF AUTO : Reglage Usine: | ||
+ | * M-8-4-08 CHANGE PUISSANCE : Reglage Usine: | ||
+ | * M-8-4-09 VENTIL EN OFF : Reglage Usine: | ||
+ | * M-8-4-10 BLOCAGE CLAVIER: Reglage Usine:off | ||
+ | * M-8-4-11 BLACK OUT : Reglage Usine: | ||
+ | * M-8-4-12 HEURES SERVICES : Reglage Usine: | ||
+ | |||
+ | === M-8-5 TEST SORTIE === | ||
+ | * M-8-5-01 TEST BOUGIE : off/on | ||
+ | * M-8-5-02 TEST VISANFIN : 0 4 | ||
+ | * M-8-5-03 TEST FUMEE : off/225U | ||
+ | * M-8-5-04 TEST VENTIL : off/225U | ||
- | M-8-4 REGLAGE GENERAL | + | === M-8-6 REGLAGE D === |
- | M-8-4-01 BLOCAGE RALLUMAGE : Reglage Usine: | + | |
- | M-8-4-02 ASP MIN ETEINT : Reglage Usine: | + | |
- | M-8-4-03 PRECHARGE ALLUMAGE : Reglage Usine: | + | |
- | M-8-4-04 ATTENTE FLAMME : Reglage Usine: | + | |
- | M-8-4-05 ASP FUME PRECHARGE : Reglage Usine: | + | |
- | M-8-4-06 DELTA ON oFF AUTO : Reglage Usine: | + | |
- | M-8-4-07 RETA OFF AUTO : Reglage Usine: | + | |
- | M-8-4-08 CHANGE PUISSANCE : Reglage Usine: | + | |
- | M-8-4-09 VENTIL EN OFF : Reglage Usine: | + | |
- | M-8-4-10 BLOCAGE CLAVIER: Reglage Usine:off | + | |
- | M-8-4-11 BLACK OUT : Reglage Usine: | + | |
- | M-8-4-12 HEURES SERVICES : Reglage Usine: | + | |
- | + | | |
- | M-8-5 TEST SORTIE | + | |
- | M-8-5-01 TEST BOUGIE : off/on | + | |
- | M-8-5-02 TEST VISANFIN : 0 4 | + | |
- | M-8-5-03 TEST FUMEE : off/225U | + | |
- | M-8-5-04 TEST VENTIL : off/225U | + | |
- | + | | |
- | M-8-6 REGLAGE D | + | |
- | M-8-6-01 MINUTES TIME-OUT: 00' | + | |
- | M-8-6-02 MINUTES DEMARRAG: 02' | + | |
- | M-8-6-03 NETTOYAGE BRASERO: 30' | + | |
- | M-8-6-04 VISANFIN ALLUMAGE: 1.2" | + | |
- | M-8-6-05 VISANFIN DEMARRAG: 1.5" | + | |
- | M-8-6-06 VISANFIN PUISSAN1: 1.0" | + | |
- | M-8-6-07 VISANFIN PUISSAN2: 1.2" | + | |
- | M-8-6-08 VISANFIN PUISSAN3: 1.5" | + | |
- | M-8-6-09 VISANFIN PUISSAN4: 1.9" | + | |
- | M-8-6-10 VISANFIN PUISSAN5: 2.3" | + | |
- | M-8-6-11 RETARD ALARME: 50" | + | |
- | M-8-6-12 NETTOYAG BRASERO: 24" | + | |
- | M-8-6-13 SEUIL MINIMUM: 45°c | + | |
- | M-8-6-14 SEUIL MAXIMUM: 275°c | + | |
- | M-8-6-15 SEUIL VENTILAT: 60°c | + | |
- | M-8-6-16 ALL-FUME VITESSE: 1850 | + | |
- | M-8-6-17 DEM-FUME VITESSE: 1600 | + | |
- | M-8-6-18 FUME VITESS 1: 1650 | + | |
- | M-8-6-19 FUME VITESS 2: 1780 | + | |
- | M-8-6-20 FUME VITESSE : 1880 | + | |
- | M-8-6-21 FUME VITESSE : 2000 | + | |
- | M-8-6-22 FUME VITESS 5: 2180 | + | |
- | M-8-6-23 VITESSE VENTIL 1: 65U | + | |
- | M-8-6-24 VITESSE VENTIL 2: 160U | + | |
- | M-8-6-25 VITESSE VENTIL 3: 185U | + | |
- | M-8-6-26 VITESSE VENTIL 4: 200U | + | |
- | M-8-6-27 VITESSE VENTIL 5: 225U | + | |
- | M-8-6-28 SEUIL ARRET: 50°c | + | |
- | M-8-6-29 ASP-FUME NETTOYAG: 2500 | + | |
- | M-8-6-30 VISANFIN NETTOYAG: 1.0" | + | |
- | M-8-6-31 ENCODER: on | + | |
- | M-8-6-32 INTERRUP TEMPS: 0.2" | + | |
- | M-8-6-33 PREMIER NETTOYAG: 20" | + | |
- | M-8-6-34 TEMPS PRECHAU: 90" | + | |
- | M-8-6-35 VIT-FUME PREM-NET: 2500 | + | |
- | M-8-6-36 VIT-FUME PR(ECHAUFFAGE): | + | |
- | M-8-6-37 VIT-FUME ATTENTE: 1750 | + | |
| | ||
| | ||
| | ||
- | M-8-7 EFFACER H PARTIEL | + | === M-8-7 EFFACER H PARTIEL |
=> CLE D' | => CLE D' | ||
- | M-8-8 EFFACER ALARME | + | === M-8-8 EFFACER ALARME |
=> CLE D' | => CLE D' | ||
- | M-8-9 MEMOIRE COMPTEUR | + | === M-8-9 MEMOIRE COMPTEUR |
- | HEURE TOTALE | + | |
- | HEURE PARTIEL | + | |
- | M-8-A VOLT ASP FUMEE | + | === M-8-A VOLT ASP FUMEE === |