Menu 8 REGLAGE TECHNIQUE ⇒ CLE D'ACCES = A9

M-8-1 TYPE GRANULES
	M-8-1-01 CHARGE GRANULES : -9~0~+9 Reglage Usine:0

M-8-2 TYPE CHEMINEE
	M-8-2-01 ASPI FUME CHEMINEE: -9~0~+9 Reglage Usine:0

M-8-3 BANQUE DONNEE DATA BANK

M-8-4 REGLAGE GENERAL
	M-8-4-01 BLOCAGE RALLUMAGE : Reglage Usine:05'
	M-8-4-02 ASP MIN ETEINT : Reglage Usine:02'
	M-8-4-03 PRECHARGE ALLUMAGE : Reglage Usine:60"
	M-8-4-04 ATTENTE FLAMME : Reglage Usine:60"
	M-8-4-05 ASP FUME PRECHARGE : Reglage Usine:1850
	M-8-4-06 DELTA ON oFF AUTO : Reglage Usine:01.0°c
	M-8-4-07 RETA OFF AUTO : Reglage Usine:02'
	M-8-4-08 CHANGE PUISSANCE : Reglage Usine:40"
	M-8-4-09 VENTIL EN OFF : Reglage Usine:220V
	M-8-4-10 BLOCAGE CLAVIER: Reglage Usine:off
	M-8-4-11 BLACK OUT : Reglage Usine:15"
	M-8-4-12 HEURES SERVICES : Reglage Usine:2000

M-8-5 TEST SORTIE
	M-8-5-01 TEST BOUGIE : off/on
	M-8-5-02 TEST VISANFIN : 0 4
	M-8-5-03 TEST FUMEE : off/225U
	M-8-5-04 TEST VENTIL : off/225U

M-8-6 REGLAGE D
	M-8-6-01 MINUTES TIME-OUT: 00'
	M-8-6-02 MINUTES DEMARRAG: 02'
	M-8-6-03 NETTOYAGE BRASERO: 30'
	M-8-6-04 VISANFIN ALLUMAGE: 1.2"
	M-8-6-05 VISANFIN DEMARRAG: 1.5"
	M-8-6-06 VISANFIN PUISSAN1: 1.0"
	M-8-6-07 VISANFIN PUISSAN2: 1.2"
	M-8-6-08 VISANFIN PUISSAN3: 1.5"
	M-8-6-09 VISANFIN PUISSAN4: 1.9"
	M-8-6-10 VISANFIN PUISSAN5: 2.3"
	M-8-6-11 RETARD ALARME: 50"
	M-8-6-12 NETTOYAG BRASERO: 24"
	M-8-6-13 SEUIL MINIMUM: 45°c
	M-8-6-14 SEUIL MAXIMUM: 275°c
	M-8-6-15 SEUIL VENTILAT: 60°c
	M-8-6-16 ALL-FUME VITESSE: 1850
	M-8-6-17 DEM-FUME VITESSE: 1600
	M-8-6-18 FUME VITESS 1: 1650
	M-8-6-19 FUME VITESS 2: 1780
	M-8-6-20 FUME VITESSE : 1880
	M-8-6-21 FUME VITESSE : 2000 
	M-8-6-22 FUME VITESS 5: 2180
	M-8-6-23 VITESSE VENTIL 1: 65U
	M-8-6-24 VITESSE VENTIL 2: 160U
	M-8-6-25 VITESSE VENTIL 3: 185U
	M-8-6-26 VITESSE VENTIL 4: 200U
	M-8-6-27 VITESSE VENTIL 5: 225U
	M-8-6-28 SEUIL ARRET: 50°c
	M-8-6-29 ASP-FUME NETTOYAG: 2500
	M-8-6-30 VISANFIN NETTOYAG: 1.0" 
	M-8-6-31 ENCODER: on
	M-8-6-32 INTERRUP TEMPS: 0.2"
	M-8-6-33 PREMIER NETTOYAG: 20"
	M-8-6-34 TEMPS PRECHAU: 90"
	M-8-6-35 VIT-FUME PREM-NET: 2500
	M-8-6-36 VIT-FUME PR(ECHAUFFAGE): 1800
	M-8-6-37 VIT-FUME ATTENTE: 1750
	
	
	
M-8-7 EFFACER H PARTIEL
=> CLE D'ACCES = 55

M-8-8 EFFACER ALARME
=> CLE D'ACCES = 55

M-8-9 MEMOIRE COMPTEUR
	HEURE TOTALE
	HEURE PARTIEL

M-8-A VOLT ASP FUMEE