poele_pellet:menu_technique
Ceci est une ancienne révision du document !
Menu 8 REGLAGE TECHNIQUE ⇒ CLE D'ACCES = A9
M-8-1 TYPE GRANULES
M-8-1-01 CHARGE GRANULES : -9~0~+9 Reglage Usine:0
M-8-2 TYPE CHEMINEE
M-8-2-01 ASPI FUME CHEMINEE: -9~0~+9 Reglage Usine:0
M-8-3 BANQUE DONNEE
M-8-4 REGLAGE GENERAL
M-8-4-01 BLOCAGE RALLUMAGE : Reglage Usine:05' M-8-4-02 ASP MIN ETEINT : Reglage Usine:02' M-8-4-03 PRECHARGE ALLUMAGE : Reglage Usine:60" M-8-4-04 ATTENTE FLAMME : Reglage Usine:60" M-8-4-05 ASP FUME PRECHARGE : Reglage Usine:1850 M-8-4-06 DELTA ON oFF AUTO : Reglage Usine:01.0°c M-8-4-07 RETA OFF AUTO : Reglage Usine:02' M-8-4-08 CHANGE PUISSANCE : Reglage Usine:40" M-8-4-09 VENTIL EN OFF : Reglage Usine:220V M-8-4-10 BLOCAGE CLAVIER: Reglage Usine:off M-8-4-11 BLACK OUT : Reglage Usine:15" M-8-4-12 HEURES SERVICES : Reglage Usine:2000
M-8-5 TEST SORTIE
M-8-5-01 TEST BOUGIE : off/on M-8-5-02 TEST VISANFIN : 0 4 M-8-5-03 TEST FUMEE : off/225U M-8-5-04 TEST VENTIL : off/225U
M-8-6 REGLAGE D
M-8-6-01 MINUTES TIME-OUT: 00' M-8-6-02 MINUTES DEMARRAG: 02' M-8-6-03 NETTOYAGE BRASERO: 30' M-8-6-04 VISANFIN ALLUMAGE: 1.2" M-8-6-05 VISANFIN DEMARRAG: 1.5" M-8-6-06 VISANFIN PUISSAN1: 1.0" M-8-6-07 VISANFIN PUISSAN2: 1.2" M-8-6-08 VISANFIN PUISSAN3: 1.5" M-8-6-09 VISANFIN PUISSAN4: 1.9" M-8-6-10 VISANFIN PUISSAN5: 2.3" M-8-6-11 RETARD ALARME: 50" M-8-6-12 NETTOYAG BRASERO: 24" M-8-6-13 SEUIL MINIMUM: 45°c M-8-6-14 SEUIL MAXIMUM: 275°c M-8-6-15 SEUIL VENTILAT: 60°c M-8-6-16 ALL-FUME VITESSE: 1850 M-8-6-17 DEM-FUME VITESSE: 1600 M-8-6-18 FUME VITESS 1: 1650 M-8-6-19 FUME VITESS 2: 1780 M-8-6-20 FUME VITESSE : 1880 M-8-6-21 FUME VITESSE : 2000 M-8-6-22 FUME VITESS 5: 2180 M-8-6-23 VITESSE VENTIL 1: 65U M-8-6-24 VITESSE VENTIL 2: 160U M-8-6-25 VITESSE VENTIL 3: 185U M-8-6-26 VITESSE VENTIL 4: 200U M-8-6-27 VITESSE VENTIL 5: 225U M-8-6-28 SEUIL ARRET: 50°c M-8-6-29 ASP-FUME NETTOYAG: 2500 M-8-6-30 VISANFIN NETTOYAG: 1.0" M-8-6-31 ENCODER: on M-8-6-32 INTERRUP TEMPS: 0.2" M-8-6-33 PREMIER NETTOYAG: 20" M-8-6-34 TEMPS PRECHAU: 90" M-8-6-35 VIT-FUME PREM-NET: 2500 M-8-6-36 VIT-FUME PR(ECHAUFFAGE): 1800 M-8-6-37 VIT-FUME ATTENTE: 1750
M-8-7 EFFACER H PARTIEL ⇒ CLE D'ACCES = 55
M-8-8 EFFACER ALARME ⇒ CLE D'ACCES = 55
M-8-9 MEMOIRE COMPTEUR
HEURE TOTALE HEURE PARTIEL
M-8-A VOLT ASP FUMEE
poele_pellet/menu_technique.1611005087.txt.gz · Dernière modification : 2021/01/18 22:24 de ptitfrap